motec_ltc

Overview

motec_ltc decodes a MoTeC LTC lambda-to-CAN module’s frames into one typed telemetry message per complete transmission. It reads the raw frames can_bridge publishes, decodes them with the generated parser for dbcs/motec/Motec_LTC_Rev1.dbc, and publishes MotecLtcTelemetry. It needs can_bridge running with the LTC on its can0 channel. It does not configure the module and decodes exactly one module, the one the DBC calls LTC_1.

Running it

The node takes only command-line options. The frame topic it reads and the prefix it publishes under are both configurable; the defaults are what a standard bring-up uses.

./build/nodes/motec_ltc/motec_ltc
Option Meaning
-s, --source Zenoh key carrying CAN frames (default vehicle/can0/rx)
-p, --prefix Key prefix for this node’s topics (default nodes/motec_ltc)
--debug Debug logging
-h, --help Print usage and exit

Logging is at debug level from the start.

Running without hardware

There is no LTC simulator in the tree. The ways to feed the node without a module are a recorded trace replayed through can_bridge’s trc: channel (see configs/can_bridge/replay.yaml), a bag recording, or hand-made frames from inspect publish on vehicle/can0/rx with schema CanFrame. The message is multiplexed over two pages, so one frame is never enough: publish a page-0 frame and a page-1 frame (first data byte 0 and then 1) and one sample appears.

Topics

Topic Schema Contents
nodes/motec_ltc/telemetry MotecLtcTelemetry Module index, lambda, pump currents ipn and ip in mA, cell resistance ri in ohm, internal temperature in C, heater duty %, battery volts, the sensor state, and seven fault flags: sensor control, internal, sensor wire short, heater failed to heat, open circuit, short to battery, short to ground

The topic sits under vehicle/, not under nodes/motec_ltc/, unlike the other decoders.

The node subscribes to vehicle/can0/rx. The one frame it decodes is LTC_1_ID1 on id 1120 (0x460), multiplexed on its first byte (LTC1_Index): page 0 carries lambda, Ipn, internal temperature, the fault bits and heater duty; page 1 carries the sensor state, battery volts, Ip and Ri. The handler fires once both pages have been seen since the last publish, so every sample carries values from one complete cycle.

sensorState is one of start, diagnostics, preCal, calibration, postCal, paused, heating, running, cooling, pumpStart, pumpOff. A raw value outside that table is published as start.

Health

The node publishes nodes/motec_ltc/health (NodeHealth) once a second, and at once whenever a check changes:

Check Degraded when
can_rx no CAN frame of any kind has arrived for a second: the bus is quiet, or the node is subscribed to the wrong key
decoded frames are arriving but none of them has been one of this node’s messages for two seconds

inspect health prints them. The node exits cleanly on SIGINT or SIGTERM, so a monitor reads a deliberate stop as exited rather than as a crash.

Services

None.

Tests

ctest --test-dir build -L motec_ltc
Target Labels Proves
motec_ltc_test_messages motec_ltc unit Each of the seven fault flags on its own, with the others clear; every sensor state mapped to its own wire value; and the two pump currents kept apart.

The mapping lives in its own library (motec_ltc_messages.h) so it can be tested without a bus: the generated decoder is checked against cantools and the schema round-trips itself, but the wiring between the two is only checked here.

Troubleshooting

Nothing on nodes/motec_ltc/telemetry. The topic is advertised as soon as the node starts, so inspect list proves only that the node is up. inspect hz vehicle/can0/rx says whether frames arrive at all; none means can_bridge is not running or the module is on a channel with another topic name, and this node cannot be redirected. Frames arriving but none on id 1120 means the LTC is transmitting on a different base identifier, which is set in MoTeC’s configuration tool; only 0x460 is decoded.

Frames on 1120 arrive and the topic still stays silent. Both multiplex pages have to arrive before anything publishes. inspect echo vehicle/can0/rx -n 20 and check the first data byte alternates between 0 and 1; a module sending only one page never completes a cycle.

The bus is empty and vehicle/can/status shows error counters climbing. That is a bit-rate mismatch presenting as silence. can_bridge’s shipped config runs can0 at 500 kbit/s; the LTC’s rate is whatever it was configured with.

Lambda reads but sensorState is never running. That is the module reporting, not the decoder: read the fault flags in the same sample, which are what the LTC says about its heater and sensor wiring.